Aptech AP64 User Manual

Browse online or download User Manual for Sensors Aptech AP64. APTech AP64 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
687 Technology Way
Napa, CA 94558
Phone: (707) 259-0102
FAX: (707) 259-0117
www.aptech-online.com
Manual 15000001 Rev 0 Page 1 of 1
Operation Manual
Check Valves
(Model AP64)
A. General information
The AP64 check valve is used in gas delivery systems to prevent reverse gas flow. A check valve
is designed to allow flow in the forward flow direction (from inlet to outlet) only.
Refer to the appropriate catalog data sheet for specific product information.
B. Installation
1. Prior to installation, verify that the operating characteristics of the check valve as
described below are appropriate for the system in which it will be installed.
a. Verify the materials of construction are compatible with the intended process gas.
b. Verify the pressure and temperature ratings are acceptable for the intended application.
c. Verify that the check valve will be used in gas service only.
2. Inspect the check valve to determine the forward flow direction as indicated by an arrow
on the AP64 body hex.
3. Install the check valve in the gas line using the appropriate method described below.
a. For tube stub connections, weld connectors or other components to the tube stubs per
standard industry practice (reference SEMI standard F78).
b. For metal face seal connectors, assemble connections per standard practice described by
fitting supplier (typically 1/8 turn past fingertight).
4. After installation, perform a helium leak test of all face seal connections and welds per
standard industry practice (reference SEMI standard F1).
C. Operation
The AP64 check valve does not require any specific action by the system operator for correct
operation once installed.
When the AP64 inlet pressure drops below the outlet pressure, the check valve will close to
prevent reverse flow. When the inlet to outlet differential pressure exceeds the cracking pressure,
then the check valve will open to allow forward flow.
Please contact the factory or your local representative to answer questions or for further
information.
Page view 0
1

Summary of Contents

Page 1 - Check Valves

687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Manual 15000001 Rev 0 Page 1 of 1 Operat

Comments to this Manuals

No comments